What should I do if the wall-hung boiler fails to ignite? Full analysis of common causes and solutions

Wall-hung boilers are important equipment for modern home heating. Once ignition failure occurs, it will not only affect the comfort of life, but may also cause safety hazards. The following are the wall-mounted boiler failure problems and solutions that have been hotly discussed on the Internet in the past 10 days, presented in structured data to help you quickly troubleshoot problems.

1. Five common reasons why wall-hung boilers fail to ignite

What to do if the wall-hung boiler fails to ignite

RankingCause of failureProbability of occurrenceTypical symptoms
1Gas supply issues42%No spark in ignition, no operating sound from gas valve
2Ignition electrode failure28%There is gas output but no spark
3Abnormal water pressure15%The pressure gauge is lower than 0.8bar or flashes the alarm
4Smoke exhaust system clogged8%Turn off the engine immediately after ignition, alarm code E5/E6
5Circuit board failure7%The display is unresponsive or garbled

2. Step-by-step troubleshooting guide

Step 1: Check the gas supply

1. Confirm whether the main gas valve is open (it is recommended to check by rotating the valve 180 degrees)
2. Check whether the balance of the gas meter is sufficient (smart meters need to insert a card to check)
3. Smell if there is any gas leakage (open flame detection is strictly prohibited)

Step 2: Verify water pressure status

Pressure valueStatus judgmentTreatment method
<0.8barNot enough pressurePressurize to 1.2-1.5bar through the water replenishment valve
0.8-2.0barnormal rangeNo action required
>3.0barPressure is too highRelieve pressure via radiator exhaust valve

Step Three: Troubleshoot the Ignition System

1.Electrode inspection:After disconnecting the power supply, gently wipe the electrode tip with fine sandpaper (the distance should be maintained at 3-5mm)
2.Spark test:After resetting, observe whether the discharge is blue-white (yellow sparks require replacing the electrode)
3.Induction needle inspection:The measured resistance value should be less than 10 ohms

3. Comparison of common fault codes of different brands

brandfault codemeaningsolution
PowerF28Ignition failureCheck the gas valve power supply line
BoschEAAbnormal combustionClean burner carbon deposits
AristonE10Water pressure is too lowReplenish water to above 1.2bar
Rinnai11Abnormal ignitionReset the motherboard or replace the ignition

4. Professional maintenance suggestions

1.Self-processing limit:It is only recommended to deal with simple faults such as gas switch and water replenishment operation.
2.Situations where repairs must be reported:Smell of gas, repeated ignition failures, circuit board fault codes
3.Service options:Prioritize contacting brand after-sales service (the average official repair fee is 15-20% lower than that of third parties)

5. Preventive maintenance guide

1.Annual maintenance:It is recommended to complete before the heating season (including 8 services such as heat exchanger cleaning and gas line inspection)
2.Consumables replacement cycle:Ignition electrode (3-5 years), gas filter (2 years), water pump (8-10 years)
3.Long-term suspension:The system should be drained of water, disconnected from the power supply and closed the gas valve

Through the above structured troubleshooting table and treatment plan, more than 90% of wall-hung boiler ignition problems can be effectively solved. In the event of a complex failure, it is recommended to save the error code information and contact professional service personnel in time to ensure the safe and stable operation of the heating system.

Next article
  • What is a Hall sensorHall sensor is a magnetic sensitive element based on the Hall effect, which is widely used in industrial control, automotive electronics, consumer electronics and other fields. It outputs electrical signals by detecting changes in magnetic fields and has the characteristics of non-contact, high precision, and long life. This article will combine the hot topics and hot content on the Internet in t
    2026-01-20 mechanical
  • What is balanced outputIn the era of information explosion, how to efficiently obtain and output valuable content has become the key. Balanced output refers to an expression method that can cover all hot spots while maintaining the depth and structure of the content during the information processing process. The following is a compilation and analysis of hot topics across the Internet in the past 10 days, using struc
    2026-01-17 mechanical
  • What material is the cold plate made of?As a common metal material, cold plate is widely used in construction, automobile manufacturing, home appliances and other fields. This article will introduce in detail the material characteristics, classification, application scenarios and related data comparison of cold plates to help readers fully understand this material.1. Definition and material characteristics of cold pl
    2026-01-15 mechanical
  • What is a clamp butterfly valveClamp butterfly valve (also known as wafer butterfly valve) is a common industrial valve that is widely used in pipeline systems to control the opening, closing and regulation of fluids. It has a simple structure, small size, light weight and flexible operation, so it is very popular in the fields of petroleum, chemical industry, electric power, water treatment and other fields. This ar
    2026-01-13 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line