How to use floor heating water distributor
The floor heating water distributor is one of the core components in the floor heating system. It is responsible for distributing hot water to various floor heating pipes to achieve uniform heating. Correct use of floor heating water distributors can not only improve heating efficiency, but also extend the service life of the equipment. This article will introduce in detail the use method, common problems and precautions of the floor heating water distributor to help users better master its operation skills.
1. Basic structure of floor heating water distributor

Floor heating water distributor usually consists of water inlet, return port, branch valve, exhaust valve, pressure gauge and other parts. Here is a detailed description of its basic structure:
| Component name | Function description |
|---|---|
| water inlet | Connect the boiler or heat source to deliver hot water to the water distributor |
| Return water outlet | Return the cooled water to the boiler for reheating |
| shunt valve | Control the flow of each branch and adjust the temperature |
| exhaust valve | Remove air from pipes to prevent air blockage |
| pressure gauge | Display system pressure to ensure normal operation |
2. How to use floor heating water distributor
1.Inspection before first use
Before using the floor heating water distributor for the first time, check whether the valves are closed to ensure that there are no leaks in the pipes. At the same time, open the exhaust valve to remove the air in the pipe, and then close the exhaust valve after the water flow stabilizes.
2.Adjust the bypass valve
According to the temperature requirements of each area of floor heating, appropriately adjust the opening of the branch valve. Generally, the greater the valve opening, the greater the flow and the higher the temperature; conversely, the temperature decreases.
3.Exhaust gas regularly
After the floor heating has been running for a period of time, air may accumulate in the pipes, affecting the heating effect. It is recommended to open the exhaust valve once a month to discharge air and ensure smooth water flow.
4.pressure monitoring
Observe the system pressure through a pressure gauge, the normal range is usually 1.5-2.0 bar. If the pressure is too low, water needs to be replenished; if the pressure is too high, the system needs to be vented or checked for malfunction.
3. Common problems and solutions
| question | Possible reasons | Solution |
|---|---|---|
| Is the floor warm or not? | The pipeline is blocked, the valve is not open, and the pressure is insufficient. | Exhaust, check valve opening, replenish water and boost pressure |
| Water distributor leaks | The sealing ring is aging and the valve is loose. | Replace sealing rings and tighten valves |
| Large pressure fluctuations | System leaks and incomplete exhaust | Check the pipes and re-exhaust |
4. Precautions
1. The floor heating water distributor should be installed in a location that is easy to operate and avoid humid or high-temperature environments.
2. Non-professionals are not allowed to disassemble the water distributor at will to avoid damaging the equipment.
3. When the floor heating is not used for a long time in winter, the water in the pipes needs to be drained to prevent freezing and cracking.
4. Clean the surface of the water distributor regularly to prevent dust from clogging the valve.
5. Summary
The correct use of floor heating water distributor is the key to ensuring the efficient operation of the floor heating system. By understanding its structure, mastering its operation methods and performing regular maintenance, you can effectively improve the heating effect and extend the life of the equipment. If you encounter a problem that cannot be solved, it is recommended to contact professional maintenance personnel.
I hope this article can help you better use the floor heating water distributor and enjoy a comfortable winter heating experience!